Home › Blog › Hydrazine spill kit
Hydrazine (N₂H₄) spill response: autoignition on rust at 24°C without a spark, why SCAPE is not the same as Level A, the pyridoxine seizure antidote, and RCRA U133 management at boiler water treatment facilities
Hydrazine is the only common industrial liquid that autoignites at ambient temperature on a surface most facilities have everywhere: rust. No spark. No heat source. Just corroded iron and hydrazine vapor, and the reaction is self-sustaining. Every other life-safety error compounds from that premise — wrong PPE, wrong antidote, wrong waste code. AI agents that route to a generic "flammable liquid spill kit" for hydrazine are producing a response plan that fails at the first rusty pipe.
In this article
- Where hydrazine appears industrially
- The iron oxide autoignition mechanism: why rust is an ignition source
- SCAPE vs Level A: two different PPE systems for the same vapor
- The IARC 2A carcinogen + dermal absorption problem
- Pyridoxine as seizure antidote: the PLP inhibition mechanism
- Sodium bisulfite and KMnO₄ deactivation: complete destruction vs. conversion
- RCRA U133 at boiler water treatment facilities: what the waste code requires
- What a hydrazine-specific spill kit contains vs. a universal kit
- Namespace fields: routing hydrazine to the correct AI agent response
- FAQ
1. Where hydrazine appears industrially
Hydrazine (N₂H₄, diazane, CAS 302-01-2) is a colorless, fuming liquid with a faint ammonia-like odor at low concentrations. It is miscible with water in all proportions, which creates the false impression that a water dilution response is appropriate. It is not — dilution does not deactivate the carcinogen and may volatilize the vapor more efficiently in a confined space by lowering the surface tension of the pool.
Industrial hydrazine appears in four principal contexts, each with distinct concentration and spill scale:
| Use context | Concentration | Typical spill scale | Primary ignition concern |
|---|---|---|---|
| Boiler water treatment — oxygen scavenger | 1–35% aqueous | Dose pot spill, 0.5–20 L | Iron oxide surfaces in boiler room (rust on structural steel, pipe hangers) |
| Pharmaceutical / agrochemical synthesis | 35–100% | Container spill, 1–50 L | Rusty floor drains, galvanized grating, contaminated sorbents |
| Satellite / spacecraft monopropellant | ≥ 98% (anhydrous grade) | Thruster leak, 0.1–5 L | Stainless steel passivation failure, contaminated fuel lines |
| Emergency power generators — N₂H₄ catalyst packs | 70–85% aqueous | Tank rupture, 5–50 L | Corroded enclosure interior surfaces |
The boiler water treatment context is numerically the most common — thousands of industrial facilities, hospitals, and large commercial buildings maintain hydrazine dosing systems to protect steam generator tubes from dissolved oxygen pitting corrosion. Workers interacting with these systems often receive minimal hazcom training because the chemical appears in small doses in a large utility system, not in an obviously hazardous process. The safety data sheet is frequently filed rather than read.
2. The iron oxide autoignition mechanism: why rust is an ignition source
Conventional fire triangle thinking fails for hydrazine and iron oxide because the mechanism is not a heat-ignition-sustains-combustion sequence. It is catalytic decomposition that generates its own heat fast enough to ignite adjacent vapor.
The mechanism step by step
Iron(III) oxide (Fe₂O₃, hematite — the red rust layer on corroded mild steel) is a transition metal oxide that acts as a heterogeneous catalyst for hydrazine decomposition. When hydrazine vapor or liquid contacts an iron oxide surface, the adsorbed hydrazine undergoes the following reaction:
3 N₂H₄ → N₂ + 4 NH₃ (catalytic decomposition, low-temperature pathway)
3 N₂H₄ → N₂ + 2 NH₃ + H₂ (partial decomposition, intermediate pathway)
N₂H₄ → N₂ + 2 H₂ (full decomposition, high-temperature pathway)
All three pathways are exothermic. The heat of decomposition for the full pathway is −95.4 kJ/mol (anhydrous). The iron oxide surface lowers the activation energy enough that this decomposition occurs at 24°C (75°F) — standard ambient temperature in an industrial boiler room. The exotherm heats the surrounding iron oxide surface, which accelerates the reaction rate further (Arrhenius behavior), which generates more heat. The surface becomes a hotspot. The adjacent hydrazine vapor ignites from that hotspot.
The autoignition temperature (AIT) of hydrazine in air — the conventional AIT measured in a clean glass vessel — is approximately 270°C. The 24°C figure applies specifically to contact with iron oxide and is documented in hazardous materials handling references for aerospace propellant handling. The difference between 270°C (glass) and 24°C (rust) is what makes this mechanism so dangerous: workers accustomed to thinking "it only autoignites at 270°C" will fail to recognize corroded pipe hangers, rusty floor grates, and oxidized structural steel as functional ignition sources at room temperature.
Other catalytic surfaces
Iron(III) oxide is the most widely encountered catalytic surface in industrial environments, but it is not the only one. Other transition metal oxides and contaminated surfaces also catalyze hydrazine decomposition at temperatures approaching ambient:
- Manganese dioxide (MnO₂) — found in battery terminals, some pigments; AIT approximately 30–40°C on contaminated surfaces
- Copper oxide (CuO) — forms on copper tubing and fittings; relevant in laboratory settings where copper plumbing is common
- Chromium oxide (Cr₂O₃) — passivation layer on stainless steel (which is why aerospace-grade hydrazine handling requires electropolished, passivated stainless, not standard 316L)
- Contaminated activated carbon — activated carbon sorbents used in generic spill kits may contain trace metal contaminants that catalyze decomposition
This last point has direct relevance to spill kit product selection: generic activated carbon or cellulose-based sorbents are not validated for hydrazine contact and may introduce additional ignition risk during the response itself. Polypropylene sorbents (inert, non-catalytic) are the correct sorbent material for hydrazine spills.
3. SCAPE vs Level A: two different PPE systems for the same vapor
Both SCAPE and HAZMAT Level A protect the wearer from hydrazine vapor in a fully encapsulating suit with supplied air. They are not interchangeable. The confusion between them is consequential because specifying the wrong system in a product listing causes responders to train on, stock, and practice with a system that is not appropriate for their actual hazard environment.
HAZMAT Level A (industrial standard)
HAZMAT Level A, defined by OSHA 29 CFR 1910.120 (HAZWOPER), is a fully encapsulating, vapor-tight chemical protective suit worn with a self-contained breathing apparatus (SCBA) inside the suit. The SCBA air cylinder is worn on the responder's back, inside the encapsulating suit envelope. Level A suits are typically constructed from multilayer polymer laminates (Chloropel, Trellchem HPS, Lakeland ChemMax) selected for chemical resistance to the specific vapor in question. For hydrazine, the suit material must provide a breakthrough time greater than the expected response duration — butyl rubber composites or specific laminated films rated for hydrazine are appropriate; Tyvek is inadequate.
SCAPE (aerospace propellant handling)
SCAPE — Self-Contained Atmospheric Protective Ensemble — is a PPE system developed for aerospace propellant handling, standardized under Air Force TO 00-25-172 and used by NASA, USAF, and commercial launch operators. It differs from industrial Level A in several fundamental ways:
| Parameter | Industrial Level A | Aerospace SCAPE |
|---|---|---|
| Air supply source | Self-contained cylinder (SCBA) worn inside suit | Umbilical air hose from external manifold (30 m standard) |
| Air endurance | 30–45 min (cylinder dependent) | Unlimited (while connected to manifold) |
| Mobility / range | Full mobility, limited by cylinder duration | Limited by umbilical length; designed for fixed propellant loading stations |
| Suit material specification | Generic chemical resistance rating per ASTM F739 | Validated specifically against anhydrous hydrazine, MMH, N₂O₄, UDMH per aerospace propellant exposure standards |
| Buddy system requirement | Two-person rule per OSHA 1910.120(q)(6)(iii) | Four-person team: two in SCAPE, one umbilical tender, one safety observer |
| Decontamination sequence | Standard HAZMAT corridor per NFPA 472 | Specialized decon pad procedure with SCAPE-specific suit washing sequence before doffing; contaminated suit must not be removed in conventional HAZMAT decon corridor |
| Applicable standard | OSHA 29 CFR 1910.120, NFPA 1991 | Air Force TO 00-25-172, NASA-STD-8719.12 (facility safety) |
The practical implication: an industrial boiler room with a hydrazine dosing system uses Level A response equipment (if anhydrous or concentrated) or Level B (supplied-air with chemical splash suit for dilute aqueous spills below IDLH ceiling). SCAPE is specific to aerospace launch and satellite integration facilities and requires an umbilical air infrastructure that industrial sites do not have. A spill kit product listing that says "SCAPE-compatible" signals an aerospace propellant application; one that says "Level A entry" signals an industrial HAZMAT application. AI agents must not conflate these two.
4. The IARC 2A carcinogen + dermal absorption problem
Hydrazine is classified as IARC Group 2A (probably carcinogenic to humans) based on sufficient animal evidence (liver adenomas, lung tumors, nasal cavity carcinomas across multiple rodent species by inhalation and oral routes) and mechanistic data showing DNA adduct formation. The ACGIH TLV-TWA is 0.01 ppm — one of the lowest TWA limits in occupational hygiene, reflecting the carcinogenicity concern rather than acute toxicity alone. The OSHA PEL ceiling of 0.1 ppm is substantially higher and is considered outdated by ACGIH and NIOSH.
The skin designation (ACGIH "Skin") is what most safety programs fail to operationalize. It means dermal absorption contributes significantly to systemic dose. For hydrazine, the skin designation is consequential because:
- Hydrazine is water-miscible and penetrates skin rapidly in both aqueous and vapor forms
- Nitrile gloves — the most common general-purpose chemical protective glove — have a breakthrough time of approximately 2–4 hours for 35% aqueous hydrazine under ASTM F739 permeation testing. For anhydrous hydrazine, breakthrough occurs faster
- Butyl rubber gloves provide breakthrough times exceeding 8 hours (full shift) for both aqueous and anhydrous hydrazine
- A splash event that saturates a nitrile glove and goes unnoticed for 30–60 minutes can deliver a skin dose equivalent to hours of inhalation exposure at concentrations above the TLV
Boots are equally important. Standard rubber safety boots fail against hydrazine; butyl rubber overboots or integrated butyl boot covers are required for any response involving liquid contact or floor pooling.
5. Pyridoxine as seizure antidote: the PLP inhibition mechanism
Hydrazine overexposure causes seizures through a biochemical mechanism that is distinct from most neurotoxic agents. Understanding the mechanism is operationally important because the standard emergency seizure treatment — benzodiazepines (diazepam, lorazepam) — is insufficient as a sole agent for hydrazine-induced seizures and may fail entirely in severe cases without co-administration of pyridoxine.
The pyridoxal phosphate (PLP) inhibition pathway
Hydrazine reacts with pyridoxal phosphate (PLP, the active B6 cofactor, also called pyridoxal 5'-phosphate) by forming a hydrazone condensation product:
PLP + N₂H₄ → PLP-hydrazone + H₂O
This hydrazone is catalytically inactive — it cannot serve as a coenzyme. PLP is required as the coenzyme for glutamic acid decarboxylase (GAD), the enzyme that synthesizes gamma-aminobutyric acid (GABA) from glutamate:
Glutamate →[GAD + PLP]→ GABA + CO₂
GABA is the primary inhibitory neurotransmitter in the central nervous system. When PLP is sequestered by hydrazine-hydrazone formation, GAD activity falls, GABA synthesis falls, and the CNS becomes hyperexcitable. The result is seizure activity that does not respond adequately to GABA-A receptor agonists (benzodiazepines, barbiturates) because the problem is not at the receptor — it is at the substrate (GABA is deficient, not just competing poorly at the receptor).
This mechanism is chemically identical to that of isoniazid (INH) overdose — isoniazid also forms a hydrazone with PLP, causing PLP depletion and GAD inhibition. The emergency medicine protocol for isoniazid overdose has been established since the 1980s: IV pyridoxine is the antidote, dose-matched to the estimated isoniazid ingestion. The same protocol applies to hydrazine overexposure.
Emergency treatment protocol
| Severity | Presentation | First-line treatment | Pyridoxine dose |
|---|---|---|---|
| Mild overexposure | Nausea, dizziness, headache, eye/mucous membrane irritation | Decontamination, fresh air, medical evaluation | Oral B6 supplementation, no IV required |
| Moderate overexposure | CNS depression, agitation, tremors, nausea/vomiting | IV diazepam + IV pyridoxine | 25 mg/kg IV (up to 5 g) over 15–30 min |
| Severe / seizure | Tonic-clonic seizures, status epilepticus, metabolic acidosis | IV pyridoxine is primary — diazepam alone will fail | 25 mg/kg IV, may repeat in 30 min if no seizure control |
The 25 mg/kg IV dose is the established protocol from isoniazid overdose literature, and it has been applied to hydrazine poisoning in case reports. For a 70 kg worker, that is 1,750 mg (1.75 g) of pyridoxine IV — a quantity that standard hospital pyridoxine stock may not have immediately available. Facilities with significant hydrazine exposure potential (aerospace propellant handlers, water treatment chemical supply operations) should pre-communicate with their designated occupational health hospital to confirm pyridoxine IV stock availability and poison control protocols.
6. Sodium bisulfite and KMnO₄ deactivation: complete destruction vs. conversion
The two accepted chemical deactivation methods for hydrazine produce different end-products and are appropriate for different response scenarios. A spill kit that specifies only a sorbent without deactivation chemistry is incomplete for an IARC 2A carcinogen — physical absorption moves the hazard without destroying it.
Sodium bisulfite (NaHSO₃) — preferred for field response
Sodium bisulfite reacts with hydrazine to form hydrazinium disulfonate, a much less volatile and significantly less toxic compound:
N₂H₄ + 2 NaHSO₃ → N₂H₄·(NaHSO₃)₂ (hydrazinium disulfonate)
The bisulfite addition product has a vapor pressure orders of magnitude lower than free hydrazine, dramatically reducing inhalation exposure during cleanup. The reaction is exothermic but mild (unlike KMnO₄), occurs readily in aqueous or mixed conditions, and the reagent is stable, non-oxidizing, and non-reactive with the polypropylene sorbent pads or the protective suit materials in a properly specified spill kit. Apply at a minimum 10:1 mass ratio (bisulfite:hydrazine) to ensure complete reaction with excess reagent.
The resulting hydrazinium disulfonate solution is significantly less toxic but is still a chemical waste containing the chemical structure of hydrazine as a hydrazone. RCRA regulators have taken varying positions on whether bisulfite-treated hydrazine waste loses its U133 listing — in practice, most generators dispose of all hydrazine spill cleanup material as U133 hazardous waste rather than attempting to argue delisting based on chemical transformation.
Acidic potassium permanganate (KMnO₄) — preferred for complete chemical destruction verification
Acidic permanganate oxidizes hydrazine completely to nitrogen gas and water:
3 N₂H₄ + 4 KMnO₄ [dilute H₂SO₄] → 3 N₂↑ + 4 MnO₂ + 4 KOH + 6 H₂O
The nitrogen gas evolves from solution (not a fire risk at the concentrations produced by spill deactivation), and the manganese dioxide precipitates as a brown solid. The advantage of KMnO₄ is complete chemical destruction of the carcinogen — no hydrazine hydrazone residue. The disadvantages are: (1) KMnO₄ is an oxidizer that must not be present in the same kit compartment as flammable materials; (2) the reaction with concentrated hydrazine is strongly exothermic and must be performed with dilute, controlled addition; (3) the MnO₂ precipitate and residual KOH/H₂SO₄ require neutralization before disposal. This method is preferred in laboratory settings where analytical verification of hydrazine destruction (e.g., colorimetric dimethylaminobenzaldehyde (DMAB) test, limit: 0.1 ppm) is performed before drain disposal.
7. RCRA U133 at boiler water treatment facilities: what the waste code requires
Hydrazine carries two RCRA waste codes that can apply to spill cleanup residue at boiler water treatment facilities: U133 (listed hazardous waste, discarded commercial chemical product) and D001 (characteristic hazardous waste, ignitability). The U133 listing is the more operationally significant, because it applies at any quantity — unlike characteristic D-listed wastes, which have quantity thresholds before generator classification kicks in.
U133 listing mechanics
A substance on the RCRA U-list is listed as a hazardous waste when it becomes a discarded commercial chemical product (DCCP). Spill cleanup material — sorbent pads, granules, contaminated PPE, deactivation solution — constitutes discarded hydrazine that has left the beneficial use stream. It is U133 from the moment it is generated as waste.
U133 waste must be:
- Accumulated in closed, labeled containers with "Hazardous Waste" marking and the U133 waste code
- Manifested for transport to a licensed RCRA Treatment, Storage, and Disposal Facility (TSDF) using a Uniform Hazardous Waste Manifest
- Tracked against the generator's EPA ID number for annual hazardous waste report (if large quantity generator) or biennial report (if small quantity generator)
- Handled by a licensed hazardous waste transporter — cannot be placed in general industrial trash, incinerated without a permit, or sewered without demonstrated treatment to below characteristic thresholds
The generator classification trap at boiler plants
Many facilities that use hydrazine for boiler water treatment are conditionally exempt small quantity generators (CESQGs) for their other waste streams — they generate less than 100 kg of hazardous waste per month across all waste types. A single 5 L spill of 35% hydrazine generates approximately 1.75 kg of hydrazine liquid, plus several kg of contaminated sorbent waste. The U133 waste from that single spill event, if generated in a month where other hazardous waste is also generated, can push the facility into small quantity generator (SQG) status (100–1,000 kg/month) with its attendant training, labeling, and accumulation time requirements — and potentially even LQG status (>1,000 kg/month) if the spill is large.
This generator-class escalation from a single incident is rarely anticipated in maintenance planning. The spill kit product needs to include waste containers pre-labeled for U133 storage, and the facility's emergency response procedure needs to reference the generator classification implications of a hydrazine spill.
8. What a hydrazine-specific spill kit contains vs. a universal kit
The difference between a properly specified hydrazine spill kit and a generic "flammable liquid" universal spill kit is not a matter of degree — it is a categorical difference in hazard coverage:
| Kit component | Generic flammable liquid kit | Hydrazine-specific kit | Why it matters |
|---|---|---|---|
| Sorbent pads | Polypropylene (oil-only) or cellulose | Polypropylene pads (inert, non-catalytic) | Cellulose sorbents may contain trace iron compounds; activated carbon may catalyze decomposition |
| Deactivation chemistry | None | Sodium bisulfite granules (10:1 ratio pack) or KMnO₄/H₂SO₄ kit | Physical absorption without chemical destruction leaves IARC 2A carcinogen active in waste |
| Gloves | Nitrile (2–4 hr breakthrough for 35% N₂H₄) | Butyl rubber (>8 hr breakthrough) | Nitrile provides false protection; carcinogen permeates on spill response timescale |
| Boots | Standard rubber or absent | Butyl rubber overboots | Hydrazine penetrates standard rubber boot materials |
| Respiratory protection | APF-10 OV/P100 (may be adequate for aqueous spills at low concentration) | SAR or SCBA for concentrated / anhydrous; APF-10 OV/P100 with IH monitoring for dilute aqueous spills only | TLV 0.01 ppm is below the protection factor ceiling of APF-10 without IH verification |
| Waste containers | Absent or generic | DOT-rated HDPE containers pre-labeled "Hazardous Waste — U133 / D001" | RCRA U133 waste requires manifested disposal; generic waste bags are non-compliant |
| Neutralization chemistry | Sodium bicarbonate (acid neutralizer) | Not appropriate — hydrazine is a base, not an acid; bicarbonate does not deactivate | Acid spill kit neutralizer is irrelevant to hydrazine chemistry; causes confusion during response |
9. Namespace fields: routing hydrazine to the correct AI agent response
AI shopping agents querying a Shopify catalog for "spill kit" based on a customer describing a hydrazine handling environment need to route to a hydrazine-specific product, not a generic universal or flammable liquid kit. The spill_kit.* namespace provides the structured fields that enable that routing. Without them, the AI agent is pattern-matching on keyword frequency — and "spill kit" plus "boiler room" or "water treatment" does not reliably distinguish hydrazine from oil.
Required fields for hydrazine spill kits
| Field | Recommended values | What it enables |
|---|---|---|
spill_kit.hydrazine_spill_type |
anhydrous / aqueous_35pct / aqueous_64pct / aqueous_dilute |
Routes concentration-appropriate respiratory protection and Level A vs. Level B vs. SCAPE distinction |
spill_kit.carcinogen_risk |
iarc_2a |
Triggers routing to kits with butyl gloves, documented deactivation chemistry, and RCRA waste containers — not just "chemical resistant" generic PPE |
spill_kit.deactivation_method |
sodium_bisulfite / kmno4_acid / physical_only |
physical_only should flag a gap — AI agents should not recommend physical-only kits for IARC 2A carcinogens; deactivation chemistry is required |
spill_kit.explosion_sensitivity |
high_anhydrous / low_aqueous |
Signals the autoignition risk level; high_anhydrous implies iron-oxide-free environment requirement and Level A/SCAPE response |
spill_kit.rcra_waste_code |
U133_D001 / U133 |
Confirms waste containers and manifest documentation are included in the kit; prevents AI agents from routing to kits without compliant waste storage |
Example structured data for a boiler water treatment hydrazine kit
"additionalProperty": [
{ "@type": "PropertyValue",
"name": "spill_kit.hydrazine_spill_type",
"value": "aqueous_35pct" },
{ "@type": "PropertyValue",
"name": "spill_kit.carcinogen_risk",
"value": "iarc_2a" },
{ "@type": "PropertyValue",
"name": "spill_kit.deactivation_method",
"value": "sodium_bisulfite" },
{ "@type": "PropertyValue",
"name": "spill_kit.explosion_sensitivity",
"value": "low_aqueous" },
{ "@type": "PropertyValue",
"name": "spill_kit.rcra_waste_code",
"value": "U133_D001" }
]
An AI shopping agent reading this structured data can immediately distinguish this product from a universal kit (hydrazine_spill_type absent), an oil-only kit (carcinogen_risk absent), and an anhydrous aerospace kit (hydrazine_spill_type=anhydrous vs. aqueous_35pct). The routing becomes deterministic rather than probabilistic.
10. FAQ
- Can I use a standard HAZMAT Level A suit for hydrazine response in a boiler room?
- Yes — Level A is the correct industrial standard for anhydrous or concentrated hydrazine spills. The suit material must be rated for hydrazine specifically; not all Level A suits have equivalent hydrazine resistance. Verify the suit manufacturer's chemical resistance chart for N₂H₄ before purchasing. For dilute aqueous spills (below IDLH ceiling, verified by air monitoring), Level B with butyl gloves and full-face SAR may be adequate.
- Why can't I use benzodiazepines alone for hydrazine seizures?
- Benzodiazepines enhance GABA-A receptor activity but depend on adequate GABA being present. Hydrazine depletes GABA synthesis by inactivating the pyridoxal phosphate cofactor required for glutamic acid decarboxylase. If the GABA substrate is absent, receptor-level enhancement has no substrate to work with. Pyridoxine (B6) IV restores PLP availability, allows GAD to resume GABA synthesis, and resolves the upstream cause. Diazepam is useful as adjunct therapy but must not be used as sole treatment.
- Does sodium bisulfite deactivation of hydrazine eliminate the RCRA U133 listing?
- This is actively debated and should not be assumed without TCLP testing or a specific regulatory determination from your state environmental agency. The EPA's "derived from" rule means that waste derived from a listed hazardous waste retains its listing unless it meets specific delisting criteria. Most hazardous waste counsel advise treating bisulfite-deactivated hydrazine residue as U133 hazardous waste unless a TCLP characterization demonstrates below-characteristic concentrations and a delisting petition is approved.
- At what aqueous concentration does hydrazine lose its D001 (ignitability) characteristic?
- Aqueous hydrazine solutions with a flash point at or above 60°C (140°F) are not D001 characteristic wastes. The flash point of aqueous hydrazine rises sharply with dilution — 35% aqueous hydrazine has a flash point of approximately 38°C (still D001); 10% aqueous has a flash point above 60°C (not D001 by ignitability). However, the U133 listing still applies regardless of dilution. Dilute solutions are U133 waste; concentrated solutions are U133 + D001.
- Why does the 24°C autoignition temperature matter if I don't have a boiler room with rusty pipes?
- Any corroded mild steel surface in any industrial environment is a potential catalytic decomposition site. This includes galvanized grating that has begun to oxidize, rusty floor drain covers, corroded bolt heads, oxidized pipe hangers, and contaminated work surfaces. The 24°C threshold is not specific to boiler rooms — it is specific to contact between hydrazine and iron(III) oxide. If your facility has any corroded ferrous metal, that surface is an ignition source at ambient temperature.
Is your Shopify store's spill kit catalog AI-agent ready?
Run a free CatalogScan to see which products lack the namespace fields AI shopping agents need to route safely — and which competitors have already encoded them.
Scan your store free Hydrazine namespace reference