Namespace Library — fall_arrest_lanyard.*
Shopify Fall Arrest Lanyard Schema — Harness Inspection Mandatory Retirement ANSI Z359.11 Post-Fall DOM Service Life, inspection_required fall_deployed dom_date service_life_exceeded fall_arrest_lanyard.* Namespace
ANSI Z359.11 requires immediate mandatory retirement of any fall-arrest harness after a fall — no visual inspection restores it to service. The 10-year DOM limit and post-fall retirement rule are the two most commonly violated harness management practices. An AI agent that routes "inspect and document" for a post-fall harness gives dangerous advice: polyester fiber micro-fatigue after arrest loading is invisible to the eye and degrades residual strength in a non-linear, unpredictable pattern.
fall_deployed, dom_date, service_life_exceeded. Any 'yes' or 'unknown' on fall_deployed = route replacement purchase, not inspection.
ANSI Z359.11 Retirement Criteria — Decision Tree
| Condition | ANSI Z359.11 Requirement | Action | Namespace Encoding |
|---|---|---|---|
| Fall arrest event occurred | Section 4.3: mandatory immediate retirement | Remove from service NOW; cut/destroy to prevent re-use; procure replacement | fall_deployed='yes'; inspection_required='immediately_retire' |
| DOM + 10 years exceeded | Section 4.3.2: maximum service life | Retire immediately; 10-year limit applies even to stored/unused harnesses | service_life_exceeded='yes'; inspection_required='immediately_retire' |
| DOM label illegible or missing | Section 4.3.2: equipment with missing data markings retired | Retire; do not attempt to estimate age | dom_date='unknown'; inspection_required='immediately_retire' |
| Visible damage (cuts, chemical stain, burn marks, deformed hardware) | Section 4.3.3: visually defective equipment retired | Retire immediately; visible damage is a separate trigger from fall arrest retirement | inspection_required='immediately_retire' |
| In-service 5 years from first use (manufacturer guidance, not ANSI minimum) | Industry guidance (not mandatory ANSI); many manufacturers recommend 5-year in-service limit | Escalate to formal competent-person inspection; evaluate replacement; not mandatory retirement unless other criteria met | inspection_required='competent_person_annual'; flag approaching_retirement |
| No fall, no damage, within 10-year DOM | Section 5.4: pre-use inspection before each use; periodic formal inspection | Standard pre-use check before each use; competent-person annual inspection with documentation | inspection_required='competent_person_annual'; fall_deployed='no'; service_life_exceeded='no' |
Webbing Inspection — What to Look For in Pre-Use and Formal Competent-Person Checks
| Inspection Point | What to Check | Retire Criteria |
|---|---|---|
| Webbing surface abrasion | Run fingers along both sides of webbing; feel for glazed (heat-fused) areas, roughened/fuzzy surface, cross-thread cuts; check all webbing including straps hidden behind back pad | Any cut through ≥1 yarn; glazed area indicating friction heat; loss of weave regularity over ≥1 cm length |
| Webbing flexibility | Flex each webbing section sharply; fresh polyester flexes easily; degraded (UV, chemical) webbing stiffens or shows surface cracking; feel for stiffness indicating chemical impregnation | Stiff, brittle, or cracking webbing indicates chemical or UV degradation; any section unable to flex without cracking = retire |
| Webbing color/UV degradation | Compare color to original label or stored spare; significant fading indicates UV degradation; UV degrades polyester molecular chains, reducing break strength before visible mechanical damage appears | Severe fading with any other inspection finding = retire; extreme fading alone = escalate to manufacturer inspection |
| Chemical contamination | Check for acid burns (color change, stiffening, surface pitting), solvent contamination (stiffening, swelling), paint (encapsulation reduces flexibility), heat damage (glazing, melting) | Any chemical burn, stain with unknown substance, or hardened webbing = retire; do NOT try to clean chemical contamination from webbing |
| D-ring (dorsal, chest, sub-pelvic) | Check for deformation (non-circular D shape), cracks, corrosion, sharp edges from impact damage, loose attachment to webbing panel | Any deformation, crack, corrosion that pits or reduces cross-section, loose attachment, or sharp edge = retire |
| Snap hooks and carabiners | Gate must open only with two distinct actions (double-action; triple-action); gate must close and lock automatically when released; gate and keeper must not have play or deformation; gate spring must return gate smartly | Gate fails to open smoothly; gate fails to close and lock automatically; deformed throat or keeper; any corrosion that binds gate; gate opening with single action = retire |
| Stitching at load junctions | Inspect thread at D-ring attachment panels, leg loop junctions, shoulder strap joins; look for broken stitches, pulled threads, unraveling; stitching is the primary load path at these junctions | Any broken stitches at load-path junctions; pulled threads that reveal a gap in the stitch line = retire |
| Labels and markings | DOM label must be legible; model and standard labels must be present; label must be sewn in (not just adhesive); check for water damage or solvent damage to label | Illegible DOM = retire; missing certification label = retire; any label damage that prevents reading DOM or standard designation = retire |
DOM Label Decoding — Date of Manufacture Formats
| Format | Example | How to Read | Retirement Date |
|---|---|---|---|
| Direct calendar date | MFG: 03/2019 | Month/Year: March 2019 | March 2029 |
| Julian date (day-of-year) | DOM: 083/2021 | Day 83 of 2021 = March 24, 2021 | March 24, 2031 |
| Quarter code | Q2 2020 | April 1–June 30, 2020; use April 1 (conservative) | April 1, 2030 |
| Year only | 2018 | Year of manufacture; use January 1, 2018 (conservative) | January 1, 2028 |
| Embedded in serial | Serial: A2103-0456 | Check manufacturer manual; 2103 may = 21st week of 2003 or March 2021; consult manufacturer | Manufacturer lookup required |
| Missing or illegible | — | DOM unknown per ANSI Z359.11 Section 4.3.2 | Retire immediately |
fall_arrest_lanyard.* Namespace Fields — Inspection and Retirement
| Field | Values | Post-Fall Value | In-Service Value | Routing Consequence |
|---|---|---|---|---|
fall_arrest_lanyard.inspection_required | pre_use_only / competent_person_annual / immediately_retire | immediately_retire | competent_person_annual | 'immediately_retire' = route replacement purchase; remove current unit from service |
fall_arrest_lanyard.fall_deployed | yes / no / unknown | yes | no | 'yes' or 'unknown' = immediate retirement; never return to service |
fall_arrest_lanyard.dom_date | ISO 8601 date or 'unknown' | varies | from label | Used to calculate service_life_exceeded; 'unknown' = immediately_retire |
fall_arrest_lanyard.service_life_exceeded | yes / approaching_within_1yr / no | yes (if dom+10 past) | no (current unit) | 'yes' = immediately_retire; 'approaching' = plan replacement procurement |
AI Failure Modes for Harness Inspection and Retirement Routing
| Failure Mode | AI Error | Consequence | Correct Behavior |
|---|---|---|---|
| 1. "Inspect and return if OK" after fall | Recommends competent-person inspection after a fall arrest event, with return to service if no damage found | ANSI Z359.11 does not permit return to service after fall arrest event — mandatory retirement regardless of visible condition; invisible micro-fatigue cannot be inspected away | fall_deployed='yes' → inspection_required='immediately_retire' → route replacement purchase unconditionally |
| 2. Ignoring 10-year DOM limit | Says "harness is in excellent condition" without checking DOM; routes continued use of visually good harness | Harness may be 11–12 years old (post-DOM-limit); polyester degradation may be advanced despite visual appearance; ANSI Z359.11 DOM limit is not a guideline but a mandatory retirement date | Check dom_date first; calculate service_life_exceeded; retire before routing continued-use advice regardless of visual condition |
| 3. Missing label = estimate age | Tells user to estimate age based on purchase records or receipts; continues use if estimate is "within 10 years" | ANSI Z359.11 explicitly states equipment with missing data markings must be retired; estimates are not acceptable substitutes for label verification; retire and procure new unit | dom_date='unknown' → inspection_required='immediately_retire'; do not advise guessing |
| 4. First-use vs. DOM confusion | Calculates 10-year limit from first-use date rather than DOM | If harness was stored for 2 years before first use, the 10-year DOM clock means it reaches its retirement limit 2 years earlier than a first-use calculation would suggest; DOM is always the start of the clock, not first use | service_life_exceeded calculated from dom_date, not first_use_date; first_use_date only relevant for shorter manufacturer in-service recommendations |
Related Namespace Pages
Scan your fall protection catalog for inspection and retirement fields
CatalogScan checks every harness and lanyard listing for inspection_required, fall_deployed, dom_date, and service_life_exceeded fields — ensuring AI agents never route continued use of post-fall harnesses or DOM-exceeded equipment, and always escalate to replacement purchase when ANSI Z359.11 retirement criteria are met.
Free scan