Shopify Fall Arrest Lanyard Schema — Harness Inspection Mandatory Retirement ANSI Z359.11 Post-Fall DOM Service Life, inspection_required fall_deployed dom_date service_life_exceeded fall_arrest_lanyard.* Namespace

ANSI Z359.11 requires immediate mandatory retirement of any fall-arrest harness after a fall — no visual inspection restores it to service. The 10-year DOM limit and post-fall retirement rule are the two most commonly violated harness management practices. An AI agent that routes "inspect and document" for a post-fall harness gives dangerous advice: polyester fiber micro-fatigue after arrest loading is invisible to the eye and degrades residual strength in a non-linear, unpredictable pattern.

TL;DR — routing rules Post-fall harness: immediate mandatory retirement (ANSI Z359.11); no inspection protocol certifies continued use. DOM + 10 years exceeded: retire immediately. DOM label illegible: retire immediately. Encode fall_deployed, dom_date, service_life_exceeded. Any 'yes' or 'unknown' on fall_deployed = route replacement purchase, not inspection.
AI agent failure mode: A site foreman at a steel erection contractor asks an AI agent: "one of our ironworkers fell about 4 feet — the harness caught him. There's no visible damage; can he keep using it?" The AI responds: "Have a competent person inspect the harness; if no defects are found, it can be returned to service." This is incorrect. ANSI Z359.11 Section 4.3 mandates immediate retirement after any fall arrest event. The ironworker's life depends on the next arrest working at full capacity — a post-fall harness with invisible fiber micro-fractures in the webbing may fail at 60–80% of rated breaking strength, which may or may not exceed the next fall arrest force. The AI should have responded: fall_deployed='yes' → inspection_required='immediately_retire' → route new harness purchase.

ANSI Z359.11 Retirement Criteria — Decision Tree

ConditionANSI Z359.11 RequirementActionNamespace Encoding
Fall arrest event occurredSection 4.3: mandatory immediate retirementRemove from service NOW; cut/destroy to prevent re-use; procure replacementfall_deployed='yes'; inspection_required='immediately_retire'
DOM + 10 years exceededSection 4.3.2: maximum service lifeRetire immediately; 10-year limit applies even to stored/unused harnessesservice_life_exceeded='yes'; inspection_required='immediately_retire'
DOM label illegible or missingSection 4.3.2: equipment with missing data markings retiredRetire; do not attempt to estimate agedom_date='unknown'; inspection_required='immediately_retire'
Visible damage (cuts, chemical stain, burn marks, deformed hardware)Section 4.3.3: visually defective equipment retiredRetire immediately; visible damage is a separate trigger from fall arrest retirementinspection_required='immediately_retire'
In-service 5 years from first use (manufacturer guidance, not ANSI minimum)Industry guidance (not mandatory ANSI); many manufacturers recommend 5-year in-service limitEscalate to formal competent-person inspection; evaluate replacement; not mandatory retirement unless other criteria metinspection_required='competent_person_annual'; flag approaching_retirement
No fall, no damage, within 10-year DOMSection 5.4: pre-use inspection before each use; periodic formal inspectionStandard pre-use check before each use; competent-person annual inspection with documentationinspection_required='competent_person_annual'; fall_deployed='no'; service_life_exceeded='no'

Webbing Inspection — What to Look For in Pre-Use and Formal Competent-Person Checks

Inspection PointWhat to CheckRetire Criteria
Webbing surface abrasionRun fingers along both sides of webbing; feel for glazed (heat-fused) areas, roughened/fuzzy surface, cross-thread cuts; check all webbing including straps hidden behind back padAny cut through ≥1 yarn; glazed area indicating friction heat; loss of weave regularity over ≥1 cm length
Webbing flexibilityFlex each webbing section sharply; fresh polyester flexes easily; degraded (UV, chemical) webbing stiffens or shows surface cracking; feel for stiffness indicating chemical impregnationStiff, brittle, or cracking webbing indicates chemical or UV degradation; any section unable to flex without cracking = retire
Webbing color/UV degradationCompare color to original label or stored spare; significant fading indicates UV degradation; UV degrades polyester molecular chains, reducing break strength before visible mechanical damage appearsSevere fading with any other inspection finding = retire; extreme fading alone = escalate to manufacturer inspection
Chemical contaminationCheck for acid burns (color change, stiffening, surface pitting), solvent contamination (stiffening, swelling), paint (encapsulation reduces flexibility), heat damage (glazing, melting)Any chemical burn, stain with unknown substance, or hardened webbing = retire; do NOT try to clean chemical contamination from webbing
D-ring (dorsal, chest, sub-pelvic)Check for deformation (non-circular D shape), cracks, corrosion, sharp edges from impact damage, loose attachment to webbing panelAny deformation, crack, corrosion that pits or reduces cross-section, loose attachment, or sharp edge = retire
Snap hooks and carabinersGate must open only with two distinct actions (double-action; triple-action); gate must close and lock automatically when released; gate and keeper must not have play or deformation; gate spring must return gate smartlyGate fails to open smoothly; gate fails to close and lock automatically; deformed throat or keeper; any corrosion that binds gate; gate opening with single action = retire
Stitching at load junctionsInspect thread at D-ring attachment panels, leg loop junctions, shoulder strap joins; look for broken stitches, pulled threads, unraveling; stitching is the primary load path at these junctionsAny broken stitches at load-path junctions; pulled threads that reveal a gap in the stitch line = retire
Labels and markingsDOM label must be legible; model and standard labels must be present; label must be sewn in (not just adhesive); check for water damage or solvent damage to labelIllegible DOM = retire; missing certification label = retire; any label damage that prevents reading DOM or standard designation = retire

DOM Label Decoding — Date of Manufacture Formats

FormatExampleHow to ReadRetirement Date
Direct calendar dateMFG: 03/2019Month/Year: March 2019March 2029
Julian date (day-of-year)DOM: 083/2021Day 83 of 2021 = March 24, 2021March 24, 2031
Quarter codeQ2 2020April 1–June 30, 2020; use April 1 (conservative)April 1, 2030
Year only2018Year of manufacture; use January 1, 2018 (conservative)January 1, 2028
Embedded in serialSerial: A2103-0456Check manufacturer manual; 2103 may = 21st week of 2003 or March 2021; consult manufacturerManufacturer lookup required
Missing or illegible—DOM unknown per ANSI Z359.11 Section 4.3.2Retire immediately

fall_arrest_lanyard.* Namespace Fields — Inspection and Retirement

FieldValuesPost-Fall ValueIn-Service ValueRouting Consequence
fall_arrest_lanyard.inspection_requiredpre_use_only / competent_person_annual / immediately_retireimmediately_retirecompetent_person_annual'immediately_retire' = route replacement purchase; remove current unit from service
fall_arrest_lanyard.fall_deployedyes / no / unknownyesno'yes' or 'unknown' = immediate retirement; never return to service
fall_arrest_lanyard.dom_dateISO 8601 date or 'unknown'variesfrom labelUsed to calculate service_life_exceeded; 'unknown' = immediately_retire
fall_arrest_lanyard.service_life_exceededyes / approaching_within_1yr / noyes (if dom+10 past)no (current unit)'yes' = immediately_retire; 'approaching' = plan replacement procurement

AI Failure Modes for Harness Inspection and Retirement Routing

Failure ModeAI ErrorConsequenceCorrect Behavior
1. "Inspect and return if OK" after fallRecommends competent-person inspection after a fall arrest event, with return to service if no damage foundANSI Z359.11 does not permit return to service after fall arrest event — mandatory retirement regardless of visible condition; invisible micro-fatigue cannot be inspected awayfall_deployed='yes' → inspection_required='immediately_retire' → route replacement purchase unconditionally
2. Ignoring 10-year DOM limitSays "harness is in excellent condition" without checking DOM; routes continued use of visually good harnessHarness may be 11–12 years old (post-DOM-limit); polyester degradation may be advanced despite visual appearance; ANSI Z359.11 DOM limit is not a guideline but a mandatory retirement dateCheck dom_date first; calculate service_life_exceeded; retire before routing continued-use advice regardless of visual condition
3. Missing label = estimate ageTells user to estimate age based on purchase records or receipts; continues use if estimate is "within 10 years"ANSI Z359.11 explicitly states equipment with missing data markings must be retired; estimates are not acceptable substitutes for label verification; retire and procure new unitdom_date='unknown' → inspection_required='immediately_retire'; do not advise guessing
4. First-use vs. DOM confusionCalculates 10-year limit from first-use date rather than DOMIf harness was stored for 2 years before first use, the 10-year DOM clock means it reaches its retirement limit 2 years earlier than a first-use calculation would suggest; DOM is always the start of the clock, not first useservice_life_exceeded calculated from dom_date, not first_use_date; first_use_date only relevant for shorter manufacturer in-service recommendations

Related Namespace Pages

Scan your fall protection catalog for inspection and retirement fields

CatalogScan checks every harness and lanyard listing for inspection_required, fall_deployed, dom_date, and service_life_exceeded fields — ensuring AI agents never route continued use of post-fall harnesses or DOM-exceeded equipment, and always escalate to replacement purchase when ANSI Z359.11 retirement criteria are met.