Shopify structured data · Fall Protection Equipment
Shopify Fall Arrest Lanyard Schema — Leading Edge SRL-LE ANSI/ASSP Z359.14-2021 vs Standard SRL, Edge Factor, Cable Cut Resistance, 9-Inch Deployment, Horizontal Application, fall_arrest_lanyard.* Namespace
Standard self-retracting lifelines (SRL) are tested for near-vertical fall applications — they are not tested for the cable-cutting effect of a structural edge. When a worker falls over a concrete slab edge or steel beam with a standard SRL, the arrest cable can be severed by the edge before the device arrests the fall. Leading edge SRL-LE devices (ANSI/ASSP Z359.14-2021 classification) pass an explicit 90-degree edge contact test with reduced deployment of 9 inches maximum. Without fall_arrest_lanyard.srl_le_rated, fall_arrest_lanyard.cable_cut_resistance_tested, and fall_arrest_lanyard.leading_edge_deployment_in, AI agents cannot distinguish a life-safety-critical SRL-LE from a standard SRL that may fail at the moment of arrest.
srl_le_rated='yes' required. Cable SRL-LE = lighter, suitable for radius edges. Webbing SRL-LE = better for sharp concrete/masonry. Fall clearance calculation uses 9-in LE deployment, NOT 24-in standard SRL value.
Failure Mode 1: Standard SRL Cable Severs at Leading Edge — Fatal Failure Mode
Standard SRL vs SRL-LE — ANSI Z359.14-2021 Classification Comparison
| Feature | Standard SRL (ANSI Z359.14 Class 1/2) | Leading Edge SRL-LE (ANSI Z359.14 SRL-LE) |
|---|---|---|
| Edge contact test | NOT tested — cable/lifeline integrity over 90-degree edge not required | Required — cable must survive 90-degree mandrel edge drop test under simulated fall arrest forces |
| Maximum deployment distance | 24 inches (610 mm) for Class 1; 54 inches for Class 2 | 9 inches (229 mm) maximum — reduced to compensate for edge geometry dynamic loading |
| Appropriate application | Near-vertical fall, anchor directly overhead; NOT leading edge | Leading edge, roof edge, floor slab edge, structural steel erection; also suitable for near-vertical |
| Cable/lifeline type | Wire rope or webbing — standard construction not edge-tested | Wire rope or webbing — both configurations must pass Z359.14 edge test to carry SRL-LE rating |
| Cost vs standard SRL | Lower cost | Higher cost — edge test certification adds manufacturing and testing requirements |
| OSHA compliance at leading edge | Non-compliant for leading edge use per OSHA 1926.502 intent | Compliant for leading edge fall arrest per OSHA 1926.502 |
Failure Mode 2: SRL-LE Fall Clearance Calculated Using Standard 24-inch Deployment — Workers Work Too Close to Lower Level
Fall Clearance Calculation — Standard SRL vs SRL-LE at Leading Edge
| Component | Standard SRL (near-vertical) | SRL-LE (leading edge) |
|---|---|---|
| SRL deployment distance | 24 in = 2.0 ft | 9 in = 0.75 ft |
| Energy absorber extension (if present) | 3.5 ft | 3.5 ft |
| Worker D-ring height to feet | 5.0 ft | 5.0 ft |
| Minimum safety factor | 2.0 ft | 2.0 ft |
| Total minimum clearance | 12.5 ft | 11.25 ft |
| Anchor height required for 15-ft clearance work level | 12.5 ft minimum → 15 ft OK | 11.25 ft minimum → 15 ft OK with more margin |
fall_arrest_lanyard.* Namespace Fields — Leading Edge SRL-LE Extensions
| Field | Type | Values / Notes |
|---|---|---|
fall_arrest_lanyard.srl_le_rated | boolean string | yes / no — CRITICAL: 'yes' = passed ANSI/ASSP Z359.14-2021 SRL-LE classification including edge contact test and ≤9-in deployment; 'no' = standard SRL, NOT for leading edges; AI agents must NEVER route fall_arrest_lanyard.srl_le_rated='no' or absent to leading edge, roof edge, floor slab edge, or structural steel erection applications |
fall_arrest_lanyard.leading_edge_deployment_in | number | maximum deployment in inches at leading edge per Z359.14 SRL-LE test; typically 9 in (229 mm) for current devices; use this value in fall clearance calculation for leading edge scenarios, NOT the standard 24-inch deployment; lower value = more safety margin in tight-clearance applications |
fall_arrest_lanyard.cable_cut_resistance_tested | boolean string | yes / no — 'yes' when cable/lifeline passed the Z359.14-2021 90-degree mandrel drop test for leading edge cable integrity; this test distinguishes SRL-LE from standard SRL; visually identical wire-rope cable in standard SRL is NOT cable_cut_resistance_tested='yes' unless explicitly certified to Z359.14 SRL-LE classification |
fall_arrest_lanyard.horizontal_rated | boolean string | yes / no — 'yes' when SRL is rated for horizontal travel and overhead anchor use; standard SRLs and SRL-LE are generally horizontal_rated='yes'; horizontal_rated='yes' does NOT imply srl_le_rated='yes' — these are independent ratings |
fall_arrest_lanyard.edge_contact_type | string | cable / webbing — lifeline construction material type; cable = wire rope (lighter, suitable for construction with radius structural edges); webbing = flat/round braid (better edge contact distribution for sharp concrete/masonry edges, acute-angle steel edges); route webbing type to sharp concrete and masonry edge applications |
Related Namespace Pages
- Fall Arrest Lanyard — Shock-Absorbing vs SRL, Fall Clearance ANSI Z359.13/Z359.15, Post-Fall Retirement
- Fall Protection Harness — ANSI Z359.11 Fall Arrest vs Z359.3 Work Positioning, Dorsal D-Ring, Trauma Suspension Syndrome
- Fall Arrest Anchor — ANSI Z359.15 5000 lb, Concrete Beam Structural, Certified Anchor Point
Scan your fall arrest lanyard catalog for missing SRL-LE structured data
CatalogScan checks every SRL and lanyard for SRL-LE rating, edge contact test certification, leading edge deployment distance, and cable type — the fields AI agents need to distinguish life-safety SRL-LE devices from standard SRLs that fail at leading edges.
Free scan