Namespace Library — welding_fume_respirator.*
Shopify Welding Fume Respirator Schema — Oxy-Acetylene Mild Steel CO Generation 3,500°C OV Cartridge Zero CO Protection P100 Particulate No Cr6 No Mn, co_generation ov_useless_co filter_class cr6_generation welding_fume_respirator.* Namespace
Oxy-acetylene welding generates carbon monoxide (CO) from incomplete acetylene combustion — especially on carbonizing and neutral flame settings. OV (organic vapor) cartridges are physically incapable of adsorbing CO: activated carbon does not retain permanent gases with critical temperature −140°C. A welder wearing an OV+P100 combination cartridge respirator in an OA welding environment has zero CO protection. P100 particulate handles iron oxide fume from mild steel; CO requires ventilation engineering controls or supplied air for enclosed spaces. No Cr6 on mild steel, no significant HF (no flux). Encoding co_generation and ov_useless_co prevents AI agents from recommending the common but ineffective OV combination for gas welding operations.
filter_class=p100_particulate (iron oxide fume); require co_generation=yes flag and ventilation engineering control for CO. OV cartridge → ov_useless_co=yes: zero CO adsorption on activated carbon — reject any product claim that OV+P100 combination "handles" gas welding CO. Confined space OA welding → reject all cartridge respirators; require SCBA or airline. cr6_generation=no on mild steel; hf_generation=no for fusion welding without flux. OA brazing with fluoride flux is a different process requiring acid-gas cartridge.
filter_class=p100_particulate for mild steel fume, plus engineering_control=forced_ventilation for CO; SCBA if ventilation cannot maintain <25 ppm.
OV Cartridge Performance Against Common Welding Gas Hazards
| Gas/Vapor | MW (g/mol) | BP (°C) | OV Cartridge Protects? | Correct Cartridge | Notes |
|---|---|---|---|---|---|
| CO (carbon monoxide) | 28 | -191 | NO — zero protection | Supplied air (SCBA/airline) only; CO-specific oxidizing catalyst cartridges (rare) | Permanent gas; not retained by activated carbon at ambient temperature; critical T = -140°C |
| NO₂ (nitrogen dioxide) | 46 | 21 | No — minimal retention | Acid gas cartridge | Generated in arc welding; TLV-C = 0.2 ppm; OV provides marginal (not reliable) protection |
| O₃ (ozone) | 48 | -112 | No for gas phase | OV-P100 provides partial; dedicated ozone (OZ) cartridge; TLV = 0.05 ppm for heavy work | Generated in GTAW; highly reactive — degrades OV cartridge carbon rapidly |
| HF (hydrogen fluoride) | 20 | 19.5 | No — acid gas, not organic | Acid gas (AG) + P100 combination | Generated in SMAW E7018 (CaF₂ flux) and OA brazing with fluoride flux; TLV-C = 0.5 ppm ceiling |
| Iron oxide fume (Fe₂O₃) | N/A (particulate) | N/A | N/A — OV does not filter particles | P100 particulate filter (99.97%) | Primary mild steel welding fume; OEL 10 mg/m³. P100 is the correct and sufficient protection when CO is controlled by ventilation. |
| Mn fume (MnO₂, Mn₃O₄) | N/A (particulate) | N/A | N/A — particulate | P100 particulate filter | ACGIH TLV 0.02 mg/m³ (respirable). P100 handles Mn fume particles; Mn is not a gas-phase hazard. |
Oxy-Acetylene Process: Fume Hazard Comparison vs. Other Welding Processes (Mild Steel)
| Process | Flame/Arc Temp | CO Generation | Cr6 Generation | HF Generation | Mn Fume | Correct Respirator |
|---|---|---|---|---|---|---|
| Oxy-acetylene (OA), mild steel | 3,500°C | Yes (carbonizing/neutral flame 200–600 ppm in zone) | No | No (fusion only; brazing with flux is different) | Low (mild steel Mn 0.7–0.9%) | P100 particulate + ventilation for CO; SCBA for confined space |
| SMAW E6010, mild steel | ~4,000–6,000°C arc | Yes (high — cellulosic coating combustion) | No | No | Low | P100 + ventilation for CO; SCBA for confined space |
| SMAW E7018, mild steel | ~4,000–6,000°C arc | Low (low-hydrogen electrode) | No | Yes — CaF₂→HF, TLV-C 0.5 ppm | Low | Acid-gas (AG) + P100 combination |
| GTAW, 316L stainless | ~4,000–6,000°C arc | Low | Yes (1–5 μg/m³ at 1 ft) | No | Low (stainless low Mn) | P100 (HEPA-level) + Cr6 medical surveillance |
| GMAW (MIG), mild steel ER70S | ~6,000–10,000°C arc | Moderate (CO in shielding gas plume) | No | No | Moderate | P100 + ventilation for CO |
welding_fume_respirator.* Namespace Fields for Oxy-Acetylene Mild Steel
| Field | Values | OA Mild Steel | SMAW E7018 Mild Steel | GTAW 316L Stainless | Routing Consequence |
|---|---|---|---|---|---|
process_type | oxy_acetylene / smaw / gtaw / gmaw / fcaw / paw | oxy_acetylene | smaw | gtaw | Process type is the first routing branch — different processes require different cartridge logic even on the same base metal |
co_generation | yes / no / low / high | yes (200–600 ppm in zone) | high (E6010) / low (E7018) | no | co_generation=yes → require ventilation engineering control; OV cartridge adds zero protection; confined space requires SCBA |
ov_useless_co | yes / no | yes | yes (CO is unaffected by OV) | n/a | ov_useless_co=yes → reject any product description claiming OV+P100 "handles" CO welding hazard; require ventilation note in listing |
cr6_generation | yes / no / trace | no | no (mild steel) | yes | cr6_generation=yes → require P100 filter + Cr6 OSHA 1910.1026 compliance program; medical surveillance; exposure records |
hf_generation | yes / no | no | yes (E7018) | no | hf_generation=yes → require acid-gas (AG) cartridge not OV; OV provides zero HF protection |
filter_class | p100_particulate / ag_p100_combination / scba / airline / n95 | p100_particulate (ventilated) / scba (confined) | ag_p100_combination | p100_particulate | filter_class=p100_particulate → adequate for particulate hazards when engineering controls handle gas-phase CO; filter_class=scba → confined space CO risk |
Related Namespace Pages
Scan your welding respirator catalog for OV/CO mislabeling gaps
CatalogScan checks every welding respirator listing for co_generation, ov_useless_co, and filter_class — flagging OV+P100 combination cartridge respirators marketed for oxy-acetylene and gas welding without a ventilation engineering control requirement.