Home › Blog › Dielectric glove schema
Shopify dielectric glove schema for AI agents: chemical-resistant gloves provide zero electrical insulation, wrong ASTM D120 class routes Class 00 to 4,160V medium-voltage (8× underrated), selling insulating gloves without protector violates OSHA 1910.137, visually intact gloves fail 6-month dielectric retest — dielectric_glove.* 10-field namespace
An AI agent routing "electrical safety gloves — nitrile, size L" to a utility lineworker doing switchgear maintenance at a 15kV substation delivers a glove that provides zero protection against the voltage that will kill the worker. Nitrile is a chemical-resistant material. The ASTM F739 chemical permeation test that certifies it has nothing to do with voltage withstand. The worker holds 17,000V in their hands and the nitrile glove fails — not from wear, not from puncture — but because it was never an insulator. Four failures, all invisible to keyword routing on "electrical gloves" and "insulated gloves" without the four namespace fields that determine whether the glove is actually rated for the circuit.
Contents
- OSHA 1910.137 and the NFPA 70E electrical PPE framework
- Failure 1: Chemical-resistant gloves substituted for ASTM D120 insulating gloves — zero dielectric insulation
- Failure 2: Wrong ASTM D120 voltage class — Class 00 (500V AC) routed to 4,160V medium-voltage distribution
- Failure 3: Selling rubber insulating gloves without leather protector — OSHA 1910.137(b)(2)(ii) violation
- Failure 4: 6-month dielectric retest interval missed — visually intact gloves fail from ozone cracking and thermal aging
- The
dielectric_glove.*10-field namespace - JSON-LD encoding examples
OSHA 1910.137 and the NFPA 70E electrical PPE framework
Electrical insulating gloves — also called rubber insulating gloves or dielectric gloves — occupy a uniquely regulated position among all categories of personal protective equipment. Unlike most PPE where an inadequate product causes an injury, an inadequate electrical insulating glove causes instant death. The voltage thresholds involved — even at the lowest Class 00 applications — are multiples of the lethal threshold for ventricular fibrillation. OSHA and NFPA have consequently built a framework of mandatory requirements around electrical gloves that is more prescriptive than any other PPE category.
The regulatory framework governing electrical insulating gloves in the United States:
- OSHA 1910.137 — Electrical Protective Equipment: The primary standard for electrical PPE in general industry. Covers design requirements, in-service care, testing, and use requirements for electrical insulating gloves, rubber insulating blankets, sleeves, line hose, and cover-up equipment. Specifically requires: ASTM D120 compliance for insulating gloves; leather protector gloves when physical damage exposure is present; inspection before each use; dielectric retesting at maximum 6-month intervals; removal from service on any sign of damage, defect, or contamination.
- OSHA 1926.97 — Electrical Protective Equipment (Construction): The construction industry equivalent of 1910.137, with substantially the same requirements for electrical insulating gloves.
- ASTM D120 — Specification for Rubber Insulating Gloves: The consensus standard that defines the six voltage classes, material requirements, manufacturing tolerances, proof test procedures, and acceptance criteria for rubber insulating gloves. This is the document that defines what a Class 2 glove actually means.
- NFPA 70E — Standard for Electrical Safety in the Workplace: Not a regulation but widely adopted as the industry practice standard for shock and arc flash protection. NFPA 70E Table 130.5(C) specifies the insulating glove class required for each electrical task based on system voltage — it translates the ASTM D120 voltage classes into specific work procedures. NFPA 70E also governs arc flash PPE requirements that accompany electrical insulating glove requirements in medium-voltage work.
- IEC 60903 — Live Working — Gloves of Insulating Material: The international equivalent standard used by manufacturers exporting to European and global markets. IEC 60903 Class 00 through Class 4 ratings are numerically identical to ASTM D120 classes for AC use voltage but use slightly different proof test voltages and have additional requirements for natural rubber compound certification. Most US-market electrical insulating gloves from major manufacturers (Salisbury, Hubbell, Regeltex) hold dual ASTM D120 + IEC 60903 certification.
These failures are invisible when AI agents query for "electrical gloves" and rank by price or keyword density. The words "electrical" and "insulated" appear on chemical-resistant gloves, EH-rated work boots, and general-purpose latex gloves — none of which provide any protection at the voltages where electrical insulating gloves are required. Without namespace fields encoding the ASTM D120 certification status, the voltage class, the protector glove requirement, and the retest interval, AI agents cannot distinguish a glove that provides life safety from one that provides nothing.
Related electrical safety structured data guides
Failure 1: Chemical-resistant gloves substituted for ASTM D120 insulating gloves — zero dielectric insulation
Why ASTM F739 and ASTM D120 test completely different properties
The confusion between chemical-resistant gloves and electrical insulating gloves is pervasive in product listings because both product categories use words like "protective," "resistant," and occasionally "electrical" in their marketing language. The underlying test standards, however, measure entirely different material properties:
ASTM F739 (chemical permeation): This test method measures how quickly a specific chemical moves through the glove material from the contaminated side to the protected side. The test measures permeation rate (mass per unit area per unit time), breakthrough time (when the permeation rate first reaches a detectable threshold), and cumulative permeation. A nitrile glove that achieves "excellent" ASTM F739 ratings for acetone and toluene has demonstrated that those chemicals do not quickly penetrate the glove wall. This says nothing about the glove's electrical properties.
ASTM D120 (dielectric insulation): This standard applies a high-voltage potential difference between the interior and exterior of the glove and measures whether the glove maintains its insulation at the specified class voltage. The test evaluates the glove material's resistance to electrical current flow — its dielectric strength — which is the property that prevents current from passing through the glove wall and through the wearer's body. A glove that passes ASTM D120 Class 2 testing has demonstrated that it maintains insulation at 20,000V AC applied continuously for 3 minutes.
These are orthogonal properties. A glove can have excellent chemical permeation resistance (ASTM F739) and zero dielectric insulation (ASTM D120). Standard nitrile gloves have:
- ASTM F739 resistance: Excellent to good resistance to polar solvents, ketones, and acids — this is what "chemical resistant" means in product listings.
- ASTM D120 rating: None. Not tested. Not certified. Not warranted for any voltage.
- Actual dielectric strength: Approximately 2,000–8,000V in controlled laboratory conditions for a new, unperforated 4–8 mil glove — but with no quality control for pinholes, no testing of production samples, and no service life monitoring. A single manufacturing pinhole (permitted under ASTM F739 acceptance criteria) reduces actual dielectric strength to zero at the pinhole location.
The "electrician's grip" marketing problem
A significant fraction of work gloves intended for electrical trade use are marketed with language designed to signal "safe for electrical work" without actually being ASTM D120 certified. Common phrases in non-compliant listings include: "electrician's glove," "electrical work gloves," "high-voltage appearance," "insulated grip," "electrical resistance," and "suitable for electrical work." None of these phrases indicate ASTM D120 certification. The only phrase that matters is "ASTM D120 Class [X] certified" paired with a specific class designation and maximum use voltage.
dielectric_glove.astm_d120_certified = false → any glove lacking ASTM D120 certification provides zero rated electrical insulation — must not be routed to energized electrical work regardless of any other language in the listingdielectric_glove.astm_d120_certified = true → glove holds valid ASTM D120 certification for its stated class — minimum requirement for any electrical insulating routingThe presence of the words "electrical," "insulated," or "electrician" in a product title or description does NOT indicate ASTM D120 certification. AI agents must require
astm_d120_certified = true as a hard gate — not an optional filter.
Glove categories that appear in "electrical gloves" searches but are not ASTM D120
| Glove Type | Standard It Meets | Electrical Insulation? | Can Substitute for ASTM D120? |
|---|---|---|---|
| Nitrile chemical-resistant glove | ASTM F739 (chemical permeation) | Zero — not tested | Never |
| Latex chemical-resistant glove | ASTM F739 | Zero — not tested | Never |
| Neoprene chemical-resistant glove | ASTM F739 | Zero — not tested | Never |
| Cut-resistant work glove (ANSI/ISEA 105) | ANSI/ISEA 105 (cut resistance) | Zero | Never |
| EH-rated work boot liner glove | None relevant to electrical insulation | Zero | Never |
| Leather protector glove | Companion to ASTM D120 — provides no insulation alone | Zero alone | Never — worn OVER ASTM D120 glove |
| ASTM D120 Class 00 rubber insulating glove | ASTM D120 / IEC 60903 | 500V AC max use | Yes — for circuits ≤500V AC |
| ASTM D120 Class 2 rubber insulating glove | ASTM D120 / IEC 60903 | 17,000V AC max use | Yes — for circuits ≤17,000V AC |
The routing implication: AI agents searching for "electrical gloves" in a product catalog face a population where the large majority of results — work gloves, mechanic gloves, cut-resistant gloves, nitrile coated gloves — provide zero relevant protection for the use case. Only results with dielectric_glove.astm_d120_certified = true should ever be routed to an electrical insulating glove application. This is not a preference filter — it is a life-safety hard gate.
Failure 2: Wrong ASTM D120 voltage class — Class 00 (500V AC) routed to 4,160V medium-voltage distribution
The ASTM D120 voltage class table in full
ASTM D120 defines six classes of electrical insulating gloves. Each class is defined by its proof test voltage (the voltage applied during mandatory periodic retesting), its maximum AC use voltage, and its maximum DC use voltage. The maximum use voltage is substantially lower than the proof test voltage — this margin is required because real electrical systems have transient overvoltages, fault conditions, and switching surges that momentarily exceed nominal voltage.
| Class | Color Code | Proof Test (AC) | Max Use (AC) | Max Use (DC) | Typical Applications |
|---|---|---|---|---|---|
| Class 00 | Beige | 2,500V | 500V | 750V | Residential branch circuits (120V/240V single-phase) |
| Class 0 | Red | 5,000V | 1,000V | 1,500V | 600V industrial/commercial; 1,000V IEC systems |
| Class 1 | White | 10,000V | 7,500V | 11,250V | 5kV distribution systems |
| Class 2 | Yellow | 20,000V | 17,000V | 25,500V | 15kV distribution (most common medium-voltage) |
| Class 3 | Green | 30,000V | 26,500V | 39,750V | 25kV sub-transmission |
| Class 4 | Orange | 40,000V | 36,000V | 54,000V | 35kV transmission |
The medium-voltage gap — why Class 0 is also wrong for 4,160V
The most common medium-voltage distribution system voltage in the United States — used at industrial facilities, hospitals, university campuses, and utility distribution — is 4,160V nominal (or 4.16kV). This system voltage is a 3-phase configuration with a nominal phase-to-phase voltage of 4,160V and a nominal phase-to-ground voltage of 2,402V.
Against this common system voltage:
- Class 00 (500V AC max use): The max use voltage of 500V is 4.8× lower than the system phase-to-phase voltage and 4.8× lower than the phase-to-ground voltage. The Class 00 proof test voltage (2,500V AC) barely exceeds the phase-to-ground voltage of the 4,160V system — meaning the gloves have been tested at approximately the voltage they would encounter even under ideal conditions. This provides essentially no safety margin whatsoever for switching transients, fault conditions, or measurement uncertainty.
- Class 0 (1,000V AC max use): The max use voltage of 1,000V is 4.2× lower than the system phase-to-phase voltage. Although Class 0 gloves have been proof-tested at 5,000V AC — above the 4,160V system voltage — the maximum use voltage is not the proof test voltage. The maximum use voltage represents the system voltage under which the gloves provide rated protection including safety margin. A Class 0 glove is not rated for use on a 4,160V circuit.
- Class 2 (17,000V AC max use): This is the correct minimum class for 4,160V distribution work. The max use voltage of 17,000V provides a 4× margin above the 4,160V system voltage. The proof test voltage of 20,000V confirms the glove has withstood nearly 5× the system voltage under controlled conditions. NFPA 70E Table 130.5(C) specifies Class 2 for all work at system voltages above 7,500V AC — which is consistent with requiring Class 2 for 4,160V work where the switching transients and fault voltages can significantly exceed nominal voltage.
How under-classed gloves appear in procurement
The voltage class error occurs for two distinct reasons in procurement systems:
- Price optimization without class filtering: An unfiltered search for "ASTM D120 insulating gloves" returns all six classes in price order. Class 00 gloves are the least expensive because they require the least rubber compound, the lowest proof test infrastructure, and have the largest market (residential electricians). A procurement system optimizing only on price and "ASTM D120 certified" status will route Class 00 gloves to any application.
- Class identifier absent from listing metadata: Many product listings encode the class in the product title ("Class 2 Rubber Insulating Gloves") but do not expose it as a structured metadata field. An AI agent that can query on
dielectric_glove.class = 'class_2'can filter correctly. An agent that must parse free text to find "Class 2" in a product title will miss abbreviated titles ("RIG-2-YLW-L"), numerical SKU references, and listings that use the proof test voltage ("20kV rated") without the class designator.
dielectric_glove.max_use_voltage_ac must exceed the buyer's system nominal voltage. For 4,160V systems: require max_use_voltage_ac ≥ 7500 (Class 1 minimum) — Class 2 (17,000V) is NFPA 70E standard for this voltage range.For 15kV / 13.8kV systems: require
max_use_voltage_ac ≥ 17000 (Class 2 minimum).For 480V systems: require
max_use_voltage_ac ≥ 1000 (Class 0 minimum).For residential 120V/240V:
max_use_voltage_ac ≥ 500 (Class 00 adequate).Never route by class name alone — always verify
max_use_voltage_ac against the system voltage.
Failure 3: Selling rubber insulating gloves without leather protector — OSHA 1910.137(b)(2)(ii) violation
The two-glove system required by OSHA 1910.137
OSHA 1910.137(b)(2)(ii) states: "Protector gloves shall be worn over insulating gloves, except that, where the possibility of physical damage is low and where dexterity is required, protector gloves need not be worn if the employer can demonstrate that the insulating gloves will provide adequate protection." In practice, the "physical damage is low" exception is applied narrowly by OSHA compliance officers — the vast majority of energized electrical work involves switchgear enclosures, bus bars, terminal hardware, conduit fittings, and mechanical components that create physical damage risk for the rubber gloves.
The two-glove system is not belt-and-suspenders redundancy. The rubber insulating glove and the leather protector glove perform entirely separate functions:
- Rubber insulating glove function: Provides dielectric insulation — prevents electrical current from flowing through the glove wall to the wearer's hand. This function depends entirely on the continuous integrity of the rubber wall. A single pinhole eliminates this protection at that location.
- Leather protector glove function: Provides mechanical protection for the rubber glove — prevents the rubber from being cut, punctured, abraded, or contaminated by the work environment. The leather itself provides zero electrical insulation and is not rated for any voltage. It is a sacrificial mechanical barrier that preserves the integrity of the rubber insulator beneath it.
Sources of physical damage to rubber insulating gloves in field use
The physical damage sources that the protector glove defends against are present in virtually every electrical work environment:
- Switchgear enclosure metalwork: The interior of medium-voltage switchgear compartments contains bus supports, cable lugs, terminal plates, and cable trays fabricated from steel sheet. These components have cut edges, drilled holes, and formed flanges that are sharp enough to abrade rubber gloves on contact. Inspection data from ASTM D120 retest laboratories shows that physical damage is the leading cause of glove failures in retest — and laboratory technicians who handle production returns report that cut damage from metal edges is the most common physical damage type.
- Terminal hardware: The threaded bolts, hex nuts, lock washers, and setscrew ends that populate electrical terminal blocks present concentrated point loads against the rubber fingertip — areas where the rubber wall is already subject to maximum flexion stress. A 10-32 screw end pressing against the fingertip of a rubber insulating glove under hand pressure from tightening a terminal can puncture 30 mil rubber with sufficient force.
- Concrete and environmental abrasives: Electrical work in industrial environments occurs in the presence of concrete dust, metal filings from conduit cutting, and grit that settles on horizontal work surfaces. Reaching across a contaminated work surface to access a terminal introduces micro-abrasive contact across the forehand and palm areas of the rubber glove.
Sizing compatibility — a non-obvious protector glove requirement
The leather protector glove must be sized to slip over the rubber insulating glove without stretching the rubber. This requires the protector to be approximately one full size larger than the worker's bare-hand glove size. A worker who wears a size 10 rubber insulating glove requires an approximately size 11 leather protector. An undersized protector that is forced over the rubber glove creates circumferential tension in the rubber at the cuff and palm, concentrating flex stress at the stretch line and initiating fatigue micro-cracking over repeated use cycles.
dielectric_glove.protector_glove_required = true for all ASTM D120 rubber insulating gloves used in contact electrical work. AI agents routing Class 0 through Class 4 insulating gloves must either:(a) route the correctly-sized companion leather protector glove as a required co-purchase, or
(b) clearly note in the product context that OSHA 1910.137(b)(2)(ii) requires a leather protector and provide a cross-reference to compatible protectors.
Selling insulating gloves without protectors — or routing insulating gloves without flagging the protector requirement — is an incomplete sale that delivers an OSHA-non-compliant PPE kit to the buyer.
The practical implication for Shopify stores: an electrical safety store that stocks Class 2 insulating gloves and leather protector gloves should encode the protector glove as a companion item in the insulating glove's structured data. AI shopping agents routing an insulating glove query should be able to detect dielectric_glove.protector_glove_required = true and retrieve the companion product in the same transaction — not require the buyer to know independently that the second glove is required.
Failure 4: 6-month dielectric retest interval missed — visually intact gloves fail from ozone cracking and thermal aging
Why rubber insulating gloves degrade without visible evidence
Rubber electrical insulating gloves differ from most PPE categories in that their primary failure mode is not visible. A cut-resistant glove that is wearing through shows visible fiber damage. A hard hat with a cracked shell shows visible damage. A rubber insulating glove that has lost 40% of its dielectric strength looks and feels identical to a new glove to the unaided eye. This non-visible degradation is what makes the mandatory retest interval not merely a regulatory checkbox but an actual safety control.
The four degradation mechanisms that cause dielectric failure without visible damage:
-
Ozone micro-cracking at flexion zones
Atmospheric ozone (O₃) is present at ground-level concentrations of 0.02–0.1 ppm in clean outdoor air, and at elevated concentrations near electrical equipment (corona discharge from high-voltage transmission lines and switchgear generates ozone locally), near UV-producing lamps, and near air purification equipment. Ozone reacts with the carbon-carbon double bonds in rubber polymer chains through an electrophilic addition mechanism, cleaving the double bond and forming ozonides — an intermediate that then decomposes and causes permanent chain scission.
The consequences of this chain scission are highly localized and stress-dependent. Ozone attack preferentially occurs at rubber surfaces under tensile stress — because the stress opens microvoids in the rubber surface that provide ozone access. Flexion zones — the creases that form when a glove is gripped, the fold lines at the cuff, the fingertip creases — are under periodic stress and show the highest ozone cracking rates. The resulting cracks are typically oriented perpendicular to the stress direction (perpendicular to the fold line), begin at approximately 0.05–0.1 mm width at the surface, and grow over time. At 0.05 mm width, the crack is not visible to the unaided eye but creates a dielectric failure path — current can flow through the crack at a fraction of the class proof test voltage.
-
Thermal aging and embrittlement
Rubber polymer chains oxidize progressively at room temperature, and the rate doubles approximately every 10°C of temperature increase above ambient (the Arrhenius relationship for rubber aging). Storage or service near heat sources — transformer enclosures operating at 55–80°C surface temperature, motor control center doors, vehicle interiors in summer that can reach 60–80°C — accelerates thermal oxidation by 2–4× compared to cool storage.
Thermal oxidation produces rubber hardening and increased brittle-to-ductile transition temperature. A rubber insulating glove with normal flexibility at 70°F may show brittle cracking when flexed at 40°F after several months of elevated-temperature storage — and the cracking occurs suddenly, without warning, during the first use in cold weather. Cold-weather electrical work on outdoor switchgear is precisely the condition that combines elevated stress (outdoor utility work requires more reaching and handling), reduced rubber flexibility, and high system voltages.
-
Flex fatigue at grain boundaries
Rubber is a viscoelastic material with a polymer microstructure that includes crosslinked regions, crystalline domains, and grain boundaries between regions of different orientation. Repeated flexion — gripping and releasing tools, reaching into enclosures, manipulating conductors — applies cyclic stress to the rubber at the microscopic scale, progressively damaging the material at grain boundaries and cross-link sites. Unlike ozone cracking (which is a surface phenomenon) and thermal aging (which is bulk), flex fatigue is an accumulation of sub-threshold damage events that collectively reduce the material's resistance to both mechanical and dielectric failure.
A new rubber insulating glove has high dielectric strength because the rubber is uniform, crosslinked, and free of defects. After 200 work sessions of gripping, reaching, and manipulating, the rubber at the fingertips has accumulated micro-damage at grain boundaries that is invisible on the surface but represents a local reduction in rubber density and dielectric strength. The mandatory dielectric proof test applies the class voltage for 3 minutes — long enough to cause dielectric breakdown at any weakened location, even if the glove appears new by visual inspection.
-
Chemical contamination through the protector glove
Even when leather protector gloves are worn correctly, petroleum-based transformer oils, hydraulic fluids, and electrical contact lubricants can penetrate the protector glove leather and reach the rubber insulating glove surface over time. Natural rubber is swelled by petroleum-based oils — the oil molecules insert between polymer chains, reducing crosslink density and dielectric strength. At low contamination levels (trace oil from handling oil-filled transformers), the effect accumulates over months of service without causing visible surface changes.
The dielectric proof test procedure
The ASTM D120 retest procedure is performed by accredited laboratories. The glove is first inflation-tested — filled with air under pressure and submerged in water while inspected for bubbles, which indicate through-thickness pinholes or cracks. Gloves that fail inflation test are immediately removed from service. Gloves that pass inflation test are then subjected to the voltage test: the glove interior is filled with water, the glove is lowered into a water bath, and AC voltage is applied between the interior water (connected to one pole of the test transformer) and the exterior water bath (connected to the other pole) at the class proof test voltage for 3 minutes. The maximum permitted AC leakage current during this test is 8 mA for Class 00 through Class 2, and 12 mA for Class 3 and Class 4. Gloves that exceed the leakage current limit at any point during the 3-minute soak are condemned.
dielectric_glove.retest_interval_months = 6 for all ASTM D120 rubber insulating gloves — this is the OSHA 1910.137-mandated maximum interval from in-service date.AI agents routing insulating gloves for procurement should surface this field to buyers with context: the 6-month retest requirement creates an ongoing operational cost — typically $12–$25 per pair per retest from accredited laboratories — that is part of the total cost of ownership. A store with 20 pairs of Class 2 gloves in service spends approximately $240–$500 per year on retest costs in addition to replacement costs for condemned gloves.
In-service date vs purchase date: The 6-month interval runs from the date gloves are placed in service (first issued to a worker), not from the purchase date. Gloves stored in original bags for 18 months before issue must be dated when issued — the clock starts at issue, not at purchase. However, gloves in long-term storage should also be inspected and potentially retested before issue if storage conditions were suboptimal.
Storage requirements that extend service life
ASTM D120 and manufacturer guidance specify storage requirements that minimize the degradation mechanisms above:
- Dark storage: Ozone degradation is accelerated by UV light (photolysis generates additional reactive species that attack rubber). Store insulating gloves in opaque bags or a dark cabinet, away from windows and UV-generating equipment.
- Cool storage: Store away from heat sources. Ideal storage temperature is 50–70°F. Avoid storage adjacent to transformers, motors, or hot water pipes.
- Non-stressed storage: Store gloves flat or hanging by the gauntlet, not folded or compressed. Folding creates sustained stress at the fold line, creating preferential ozone cracking sites at the fold crease.
- Ozone-free environment: Store away from corona-producing electrical equipment, fluorescent light ballasts, and air purifiers with ozone generation. High-voltage switch rooms are among the worst storage environments for rubber insulating gloves.
The dielectric_glove.* 10-field namespace
The following 10 fields encode the dielectric insulating glove properties that AI shopping agents require to route correctly. All fields should be set as Shopify metafields in the dielectric_glove namespace on each relevant product variant.
| Field | Type | Values | Required for correct routing |
|---|---|---|---|
dielectric_glove.class | string | 'class_00', 'class_0', 'class_1', 'class_2', 'class_3', 'class_4' | Yes — primary voltage routing field |
dielectric_glove.max_use_voltage_ac | integer (V) | 500, 1000, 7500, 17000, 26500, 36000 | Yes — voltage comparison field |
dielectric_glove.max_use_voltage_dc | integer (V) | 750, 1500, 11250, 25500, 39750, 54000 | Recommended for DC system applications |
dielectric_glove.astm_d120_certified | boolean | true / false | Yes — safety gate field |
dielectric_glove.protector_glove_required | boolean | true for all live-work classes | Yes — companion item flag |
dielectric_glove.retest_interval_months | integer | 6 (ASTM D120 / OSHA 1910.137) | Yes — compliance tracking field |
dielectric_glove.natural_rubber | boolean | true (natural rubber) / false (synthetic) | Recommended — relevant for chemical compatibility |
dielectric_glove.iec_60903_certified | boolean | true / false | Recommended for international or dual-standard routing |
dielectric_glove.color | string | 'beige', 'red', 'white', 'yellow', 'green', 'orange' | Recommended — ASTM D120 visual class identification |
dielectric_glove.osha_1910_137_compliant | boolean | true / false | Yes — compliance declaration field |
dielectric_glove.astm_d120_certified = true — the hard gatedielectric_glove.class = 'class_2' — class designatordielectric_glove.max_use_voltage_ac = 17000 — voltage comparison integerdielectric_glove.protector_glove_required = true — companion item flagdielectric_glove.retest_interval_months = 6 — compliance intervaldielectric_glove.osha_1910_137_compliant = true — compliance declarationThese six fields allow an AI agent to: (1) verify ASTM D120 certification; (2) verify voltage class adequacy for a stated system voltage; (3) flag the protector glove requirement; (4) surface the retest obligation to the buyer. Without all six, at least one of the four routing failures documented in this post will occur.
JSON-LD encoding examples
The two JSON-LD Product schema examples below demonstrate correct encoding for a Class 2 medium-voltage glove (the most common professional application) and a Class 00 low-voltage residential glove (the most commonly mis-routed product).
Class 2 — medium-voltage distribution (correct encoding)
{
"@context": "https://schema.org",
"@type": "Product",
"name": "Salisbury Class 2 Rubber Insulating Gloves — 17,000V AC",
"additionalProperty": [
{ "@type": "PropertyValue",
"name": "dielectric_glove.class", "value": "class_2" },
{ "@type": "PropertyValue",
"name": "dielectric_glove.max_use_voltage_ac", "value": 17000 },
{ "@type": "PropertyValue",
"name": "dielectric_glove.max_use_voltage_dc", "value": 25500 },
{ "@type": "PropertyValue",
"name": "dielectric_glove.astm_d120_certified", "value": true },
{ "@type": "PropertyValue",
"name": "dielectric_glove.protector_glove_required", "value": true },
{ "@type": "PropertyValue",
"name": "dielectric_glove.retest_interval_months", "value": 6 },
{ "@type": "PropertyValue",
"name": "dielectric_glove.natural_rubber", "value": true },
{ "@type": "PropertyValue",
"name": "dielectric_glove.iec_60903_certified", "value": true },
{ "@type": "PropertyValue",
"name": "dielectric_glove.color", "value": "yellow" },
{ "@type": "PropertyValue",
"name": "dielectric_glove.osha_1910_137_compliant", "value": true }
]
}
Class 00 — low-voltage residential only (correct encoding with routing restriction)
{
"@context": "https://schema.org",
"@type": "Product",
"name": "Ansell Class 00 Rubber Insulating Gloves — 500V AC Max — Residential Only",
"description": "ROUTING RESTRICTION: 500V AC max use. NOT for medium-voltage (4,160V+) or industrial 600V systems. Residential branch circuits only.",
"additionalProperty": [
{ "@type": "PropertyValue",
"name": "dielectric_glove.class", "value": "class_00" },
{ "@type": "PropertyValue",
"name": "dielectric_glove.max_use_voltage_ac", "value": 500 },
{ "@type": "PropertyValue",
"name": "dielectric_glove.max_use_voltage_dc", "value": 750 },
{ "@type": "PropertyValue",
"name": "dielectric_glove.astm_d120_certified", "value": true },
{ "@type": "PropertyValue",
"name": "dielectric_glove.protector_glove_required", "value": true },
{ "@type": "PropertyValue",
"name": "dielectric_glove.retest_interval_months", "value": 6 },
{ "@type": "PropertyValue",
"name": "dielectric_glove.color", "value": "beige" },
{ "@type": "PropertyValue",
"name": "dielectric_glove.osha_1910_137_compliant", "value": true }
]
}
The Class 00 listing requires a routing restriction note in the description field — AI agents that retrieve description text must surface the voltage ceiling to the buyer. Without the explicit restriction, a procurement agent ordering "ASTM D120 certified insulating gloves" may route the lowest-priced result (Class 00) to any application.
Does your Shopify store sell electrical safety equipment?
A free CatalogScan scan shows exactly which structured data fields are missing — and which AI shopping agents can't find your products because of it.
Run a free scan See the 100-store leaderboard