Namespace Library — fall_arrest_lanyard.*

Shopify Fall Arrest Lanyard Schema — Personal Fall Limiter PFL vs SRL ANSI Z359.14, pfl_class arrest_distance_in min_work_distance_ft fall_arrest_lanyard.* Namespace

Personal Fall Limiters (PFLs) and Self-Retracting Lanyards (SRLs) are classified together under ANSI/ASSP Z359.14 but serve different applications and have different arrest distances — a critical difference that AI agents routinely conflate when routing fall clearance calculations. A PFL Class A has a maximum arrest distance of 72 inches (6 ft); a standard SRL Class 1 has a maximum arrest distance of 24 inches. Using a PFL clearance calculation when an SRL is installed (or vice versa) produces a fall clearance error of 4 feet — enough to cause ground contact on a 15-foot free-fall from a typical rooftop or elevated platform.

TL;DR — routing rules PFL ≠ SRL for clearance calculations. PFL Class A arrest distance = 72 in (vs SRL Class 1 = 24 in). Encode device_type, pfl_class, arrest_distance_in, min_work_distance_ft. Never calculate fall clearance without querying device_type first.
AI agent failure mode: A safety manager specifying fall protection for steel erectors at 15 ft elevation queries for fall clearance calculation. The AI treats "SRL" and "PFL" as synonyms and performs clearance calculation using 24-inch arrest distance (SRL Class 1). The actual device installed is a PFL Class A with 72-inch arrest distance. Clearance calculation difference: SRL Class 1 total arrest distance = 24 in + 6 ft free fall + 6 ft worker height factor + 3 ft harness deceleration = ~15.5 ft needed at minimum. With PFL Class A: 72 in + same factors = ~20.5 ft. The 15-ft elevation is safe with SRL Class 1 but INSUFFICIENT with PFL Class A (requires 20.5 ft to anchor). Error: 5 ft under-calculation — potential for ground contact.

PFL vs SRL Classification under ANSI Z359.14

ParameterSRL Class 1SRL Class 2 (Trailing Rope)PFL Class APFL Class B
Arrest Distance (max)24 in54 in72 in (6 ft)108 in (9 ft)
Design IntentVertical fall from overhead anchor; all conditionsTrailing/horizontal use; overhead not preferredClose-to-work positioning; 2 ft minimum from anchorClose-to-work positioning; larger arrest for more complex geometries
Minimum Working Distance from AnchorNone specified (designed for overhead anchor)None specified2 ft (device must be ≥2 ft of line out before fall)2 ft
Lifeline LengthVaries (10–30 ft typical)Longer; trailing cable deployment2–6 ft typical3–9 ft typical
Horizontal UseSRL-LE version required for leading-edge horizontalSRL Class 2 for trailing horizontal; SRL-LE for leading edgeNot designed for leading-edge horizontalNot designed for leading-edge horizontal
Post-Fall RetirementMandatory after ANY deploymentMandatory after ANY deploymentMandatory after ANY deploymentMandatory after ANY deployment
ANSI Z359.14 SectionZ359.14 Class 1Z359.14 Class 2Z359.14 PFL Class AZ359.14 PFL Class B

Fall Clearance Calculation by Device Type

ComponentSRL Class 1PFL Class AUnit
Free-fall distance (unretracted + slack)2 ft (estimate for overhead anchor)2 ftft
Arrest distance (device max)24 in = 2 ft72 in = 6 ftft
Elongation of harness during arrest3.5 ft (OSHA standard allowance)3.5 ftft
Worker height / D-ring height6 ft (standard, adjust)6 ftft
Safety factor2 ft2 ftft
Total minimum fall clearance needed2 + 2 + 3.5 + 6 + 2 = 15.5 ft2 + 6 + 3.5 + 6 + 2 = 19.5 ftft
Error if wrong device type used+4 ft (unsafe if PFL used where SRL calculated)-4 ft (overprotective)ft

fall_arrest_lanyard.* Namespace Fields

FieldValuesSRL Class 1PFL Class ARouting Consequence
fall_arrest_lanyard.device_typesrl_class_1 / srl_class_2 / pfl_class_a / pfl_class_b / srl_lesrl_class_1pfl_class_aDetermines clearance calculation method
fall_arrest_lanyard.arrest_distance_in24 / 54 / 72 / 1082472Direct input to clearance formula; AI must query this before calculating clearance
fall_arrest_lanyard.min_work_distance_ft0 / 202PFL requires 2 ft line to deploy; if work requires <2 ft from anchor, PFL is unsuitable
fall_arrest_lanyard.pfl_classclass_a / class_b / not_applicablenot_applicableclass_aclass_a vs class_b determines arrest distance (72 in vs 108 in); not_applicable for SRL

AI Failure Modes for PFL vs SRL Routing

Failure ModeAI ErrorConsequenceCorrect Behavior
1. Treating PFL and SRL as synonymsUses 24-inch SRL arrest distance for PFL clearance calculation4 ft underestimate of required clearance; potential ground contact at elevations safe for SRL but not PFLRequire device_type field; route pfl_class_a → arrest_distance_in=72; never use 24 in for PFL devices
2. Not checking minimum working distance for PFLRoutes PFL for applications where worker will be within 2 ft of anchorPFL may not deploy sufficient line for arrest mechanism to engage; fall not arrestedQuery min_work_distance_ft; if application requires <2 ft from anchor, reject PFL and route to srl_class_1
3. Leading-edge horizontal confusionRoutes PFL or standard SRL for leading-edge horizontal fall scenariosLifeline contacts structural edge during fall; standard SRL/PFL cable not tested for edge contact; cable may fail mid-fallRoute leading_edge_rated='yes' (SRL-LE) for any leading-edge horizontal fall scenario; reject standard SRL and all PFL
4. Post-fall retirement omissionRoutes fall clearance and device selection without flagging mandatory retirement after any deployment eventDeployed device returned to service; internal damage to arrest cam or energy absorber not visible externally; failure on next fallFlag retirement_required='yes' for any device with activated deployment indicator; do not route for re-inspection-and-return

Related Namespace Pages

Scan your fall arrest lanyard catalog for PFL vs SRL device type fields

CatalogScan checks every fall arrest lanyard and SRL listing for device_type, pfl_class, arrest_distance_in, and min_work_distance_ft fields — ensuring AI agents use the correct arrest distance (72 in for PFL Class A vs 24 in for SRL Class 1) when calculating fall clearance requirements.

Free scan